+86-312-6775656
Charge vide du transformateur HZKZ-50A et équipement de test de pertes à vide

Charge vide du transformateur HZKZ-50A et équipement de test de pertes à vide

Charge vide du transformateur HZKZ-50A et équipement de test de pertes à vide I. Overview HZKZ-50A Transformer On-No Load Characteristics Tester is the latest product of Huazheng Electric Manufacturing (Baoding) Co., Ltd. The instrument adopts the popular ARM processor in this year, with 168M basic frequency and...
Product Details ofCharge vide du transformateur HZKZ-50A et équipement de test de pertes à vide

 

Charge vide du transformateur HZKZ-50A et équipement de test de pertes à vide

Transformer No Load Loss Test

I. Overview

HZKZ-50A Transformer On-No Load Characteristics Tester is the latest product of Huazheng Electric Manufacturing (Baoding) Co., Ltd. The instrument adopts the popular ARM processor in this year, with 168M basic frequency and 128m memory, which can be expanded to 4G memory card. Using 7-inch high-definition color touch panel, combined with emwin display interface so as to make the instrument interface being friendly and operated in a simple way, it can be operated through the touchscreen without keyboard. The instrument support database and can be exported through USB disk or transmitted to computer via data wire.
The circuit design of this instrument is exquisite and unique, which makes it superior in performance, powerful in function, small in size and light in weight. It can not only be used to test the on-no load parameters of transformer, but also measure the harmonic content and waveform in the field. The instrument can record the test curve of transformer under on-no load condition, then provide reliable basis for transformer fault analysis.

II. Main Technical Specifications

1 Voltage measurement   scope: AC 101000V

2 Current measurement   scope: AC 0.1 50 A

3 Measurement accuracy: voltage: 0.1 percent ±0.005V (frequency 4070Hz)

{{0}}.5 percent ±0.005V (frequency 70200Hz)

Current: {{0}}.1 percent ±0.0002A (frequency 4070Hz)

{{0}}.5 percent ±0.0002A (frequency 70200Hz)

Power: P{{0}}.1 percent ± (UI0.02 percent ) ±0.05W (P is power factor, U is reading of voltage effective value, I is reading of current effective value)

Packing List

No.

Item

Qty

1

Main engine

1

2

Power line

1

3

Ground lead

1

4

Touch Pen

1

5

Fuse pipe

2

6

Print paper

1

7

Voltage line

1

8

Current line

1

image014

image016

image018

étiquette à chaud: Charge vide du transformateur HZKZ-50A et équipement de test de pertes à vide, China, suppliers, manufacturers, price, for sale, Transformer No Load Loss Tester, load loss and no load loss of transformer tester, transformer core loss tester, copper loss and iron loss test equipment, HZKZ-50A, No Load Loss Test on Power Transformer, No-load Load loss measurement, HZKZ50A transformer copper loss test set

Envoyez demande

(0/10)

clearall